  Q2. Setting and realizing of anti-theft function.  
 
  Two codes for anti-theft functions 4093 and 4094, audio guide unit will alarm to remind visitors return back it when  
  triggered by the two codes.  
  Alarm time can be set from 0-30 minutes by code 4093 or 4094. (This parameter should be set on WD-900)  
     
  Setting of immediate alarm  
  . Set alarm time as 0 minute;  
  . Audio guide will alarm immediately once it entered trigger zone of 4093 or 4094.  
     
  Setting of delayed alarm  
  This setting is always used for only alarm when exiting, no alarm when entering.  
  Following conditions should be met to set delayed alarm, audio guide will alarm after the setting time.  
  . Alarm time was set in the range of 1-30 minutes;  
  . AG-600 should leave this trigger zone after it triggered by codes 4093 or 4094;  
  . Also, only the AG-600 has been used will realize delayed alarm, one of the two conditions must be met:  
  Audio guide has already been trigger played automatically.  
  Audio guide has played 3 complete audios by keypad manually.(Ignore this, if your model is AG-600N)  
 
 
 
 
 